Шкафы управления 4 насосами подпитки

Назначение

Управление насосами

Тип управления

Релейное регулирование

Кол-во насосов

4

Мощность

0-75 кВт

Плавный пуск (УПП)

Да (опция)

Материал корпуса

Металл

Исполнение корпуса

УХЛ4

Производитель
Код ШУПусковая системаМощность,кВтНом. ток, АГабариты ШУ, мм (ВхШхГ)
без АВРс АВР
3R-M(A)-22D1K6Прямой пуск (схема 34 стр. 60)0,551,6800x800x250800x800x250
3R-M(A)-22D2K50,752,5800x800x250800x800x250
3R-M(A)-22D0041,1/1,54800x800x250800x800x250
3R-M(A)-22D6K32,26,3800x800x250800x800x250
3R-M(A)-22D0103/410800x800x250800x800x250
3R-M(A)-22D0145,514800x800x250800x800x250
3R-M(A)-22D0187,518800x800x250800x800x250
3R-M(A)-22S023УПП (схема 35 стр. 61)9231000x800x2501000x800x250
3R-M(A)-22S02511251000x800x2501000x800x250
3R-M(A)-22S03215321000x800x2501000x800x250
3R-M(A)-22S04018,5401200x1200x3001200x1200x300
3R-M(A)-22S05022501200x1200x3001200x1200x300
3R-M(A)-22S06330631200x1200x3001200x1200x300
3R-M(A)-22S08037801900x1000x4001900x1200x400
3R-M(A)-22S100451001900x1000x4001900x1200x400
3R-M(A)-22S125551251900x1200x4001900x1200x400
3R-M(A)-22S140751401900x1200x4001900x1200x400
3R-M(A)-22H1K9ЧРП (схема 36 стр. 62)0,551,9800x800x3001000x800x300
3R-M(A)-22H2K30,752,3800x800x3001000x800x300
3R-M(A)-22H0031,13800x800x3001000x800x300
3R-M(A)-22H4K11,54,1800x800x3001000x800x300
3R-M(A)-22H5K52,25,5800x800x3001000x800x300
3R-M(A)-22H7K137,1800x800x3001000x800x300
3R-M(A)-22H9K549,5800x800x3001000x800x300
3R-M(A)-22H0145,514,31200x1000x3001200x1000x300
3R-M(A)-22H0177,5171200x1000x3001200x1000x300
3R-M(A)-22H0279/1127,71200x1000x3001200x1200x300
3R-M(A)-22H03315331200x1000x3001200x1200x300
3R-M(A)-22H03918,539,21900x1000x4001900x1000x400
3R-M(A)-22H0462246,31900x1000x4001900x1000x400
3R-M(A)-22H0613061,52100x1200x4002100x1200x400
3R-M(A)-22H0743774,52100x1200x4002100x1200x400
3R-M(A)-22H08745882100x1200x4002100x1200x400
3R-M(A)-22H106551061900x1800x4001900x2000x400
3R-M(A)-22H145751451900x1800x4001900x2000x400
Код ШУПусковая системаМощность,кВтНом. ток, АГабариты ШУ, мм (ВхШхГ)
без АВРс АВР
3R-M(A)-31D1K6Прямой пуск (схема 34 стр. 60)0,551,6800x800x250800x800x250
3R-M(A)-31D2K50,752,5800x800x250800x800x250
3R-M(A)-31D0041,1/1,54800x800x250800x800x250
3R-M(A)-31D6K32,26,3800x800x250800x800x250
3R-M(A)-31D0103/410800x800x250800x800x250
3R-M(A)-31D0145,514800x800x250800x800x250
3R-M(A)-31D0187,518800x800x250800x800x250
3R-M(A)-31S023УПП (схема 35 стр. 61)9231000x800x2501200x800x300
3R-M(A)-31S02511251000x800x2501200x800x300
3R-M(A)-31S03215321000x800x2501200x800x300
3R-M(A)-31S04018,5401200x1000x3001200x1200x300
3R-M(A)-31S05022501200x1000x3001200x1200x300
3R-M(A)-31S06330631200x1000x3001200x1200x300
3R-M(A)-31S08037801900x1000x4001900x1200x400
3R-M(A)-31S100451001900x1000x4001900x1200x400
3R-M(A)-31S125551251900x1200x4001900x1200x400
3R-M(A)-31S140751401900x1200x4001900x1200x400
3R-M(A)-31H1K9ЧРП (схема 36 стр. 62)0,551,9800x800x3001000x800x300
3R-M(A)-31H2K30,752,3800x800x3001000x800x300
3R-M(A)-31H0031,13800x800x3001000x800x300
3R-M(A)-31H4K11,54,1800x800x3001000x800x300
3R-M(A)-31H5K52,25,5800x800x3001000x800x300
3R-M(A)-31H7K137,1800x800x3001000x800x300
3R-M(A)-31H9K549,5800x800x3001000x800x300
3R-M(A)-31H0145,514,31200x1000x3001200x1200x300
3R-M(A)-31H0177,5171200x1000x3001200x1200x300
3R-M(A)-31H0279/1127,71200x1000x3001200x1200x300
3R-M(A)-31H03315331200x1000x3001200x1200x300
3R-M(A)-31H03918,539,21900x1000x4001900x1000x400
3R-M(A)-31H0462246,31900x1000x4001900x1000x400
3R-M(A)-31H0613061,52100x1200x4002100x1200x400
3R-M(A)-31H0743774,52100x1200x4002100x1200x400
3R-M(A)-31H08745882100x1200x4002100x1200x400
3R-M(A)-31H106551061900x1800x4001900x2000x400
3R-M(A)-31H145751451900x1800x4001900x2000x400
Код ШУПусковая системаМощность,кВтНом. ток, АГабариты ШУ, мм (ВхШхГ)
без АВРс АВР
3R-M(A)-40D1K6Прямой пуск (схема 34)0,551,6800x800x2501000x800x250
3R-M(A)-40D2K50,752,5800x800x2501000x800x250
3R-M(A)-40D0041,1/1,54800x800x2501000x800x250
3R-M(A)-40D6K32,26,3800x800x2501000x800x250
3R-M(A)-40D0103/410800x800x2501000x800x250
3R-M(A)-40D0145,514800x800x2501000x800x250
3R-M(A)-40D0187,518800x800x2501000x800x250
3R-M(A)-40S023УПП (схема 35)9231000x800x2501200x800x300
3R-M(A)-40S02511251000x800x2501200x800x300
3R-M(A)-40S03215321000x800x2501200x800x300
3R-M(A)-40S04018,5401200x1000x3001200x1200x300
3R-M(A)-40S05022501200x1000x3001200x1200x300
3R-M(A)-40S06330631200x1000x3001200x1200x300
3R-M(A)-40S08037801900x1000x4001900x1200x400
3R-M(A)-40S100451001900x1000x4001900x1200x400
3R-M(A)-40S125551251900x1200x4001900x1200x400
3R-M(A)-40S140751401900x1200x4001900x1200x400
3R-M(A)-40H1K9ЧРП (схема 36)0,551,9800x800x3001000x800x300
3R-M(A)-40H2K30,752,3800x800x3001000x800x300
3R-M(A)-40H0031,13800x800x3001000x800x300
3R-M(A)-40H4K11,54,1800x800x3001000x800x300
3R-M(A)-40H5K52,25,5800x800x3001000x800x300
3R-M(A)-40H7K137,1800x800x3001000x800x300
3R-M(A)-40H9K549,5800x800x3001000x800x300
3R-M(A)-40H0145,514,31200x1000x3001200x1200x300
3R-M(A)-40H0177,5171200x1000x3001200x1200x300
3R-M(A)-40H0279/1127,71200x1000x3001200x1200x300
3R-M(A)-40H03315331200x1000x3001200x1200x300
3R-M(A)-40H03918,539,21900x1000x4001900x1000x400
3R-M(A)-40H0462246,31900x1000x4001900x1000x400
3R-M(A)-40H0613061,52100x1200x4002100x1200x400
3R-M(A)-40H0743774,52100x1200x4002100x1200x400
3R-M(A)-40H08745882100x1200x4002100x1200x400
3R-M(A)-40H106551061900x1800x4001900x2000x400
3R-M(A)-401H145751451900x1800x4001900x2000x400

Шкафы управления FNB CONTROL 3R предназначены для поддержания необходимого давления жидкости в системах с закрытым контуром путем включения/выключения необходимого количества насосов. 

 

Шкафы управления FNB CONTROL 3R применяются в системах: 

– холодного водоснабжения (ХВС); 

– горячего водоснабжения (ГВС); 

отопления; 

холодоснабжения; 

водоподготовки. 

 

Основные функции шкафов управления FNB CONTROL 3R: 

– автоматическое поддержание заданного давления в системе; 

– возможность регулирования давления в подающем трубопроводе при использовании частотного преобразователя; 

– автоматическое включение резервного насоса в случае аварии основного работающего насоса; 

– снижение пиковых электрических и механических нагрузок на систему; 

– защита насосов по «сухому ходу»; 

– защита насосов по температуре (при наличии соответствующей защиты); 

– автоматический запуск системы после сброса аварийных ситуаций;  

– выравнивание износа насосных агрегатов с контролем времени наработки каждого насоса.

Данная система имеет три режима работы: Ручной, Автоматический и Дистанционный. Выбор режима работы осуществляется путем поворота переключателя режима работы на двери ШУ в соответствующее положение. Ручной режим работы: управление насосами происходит от кнопок «Пуск»/«Стоп» соответствующего насоса, расположенных на двери ШУ либо на пультах местного управления (опция), с отображением индикации состояния. Дистанционный режим работы: управление насосами происходит от внешнего сигнала («сухой контакт»). Автоматический режим работы: управление насосами происходит по датчикам давления. Реле давления на всасывающем коллекторе: Предназначено для защиты насосов от «сухого хода». Датчик (реле) давления на напорном трубопроводе: Предназначен для управления насосами по уставкам давлений. По алгоритму, заложенному в шкаф управления FNB CONTROL 3R, система непрерывно производит мониторинг состояний и показаний датчиков. Защита от «сухого хода» обеспечивается реле давления на всасывающем трубопроводе. Датчик давления на напорном трубопроводе предназначен для включения — выключения насосов. При падении давления в системе ниже заданного включается первый основной насос. Если в течение заданного времени давление в системе не достигло нужного значения, последовательно включаются следующие основные насосы. При достижении необходимого давления в системе все насосы выключаются. При использовании частотного преобразователя возможно реализовать регулирование производительности насоса, что позволяет поддерживать в системе постоянное давление. В этом случае основной насос работает на определенной частоте, поддерживая необходимое давление. При увеличении расхода и падении давления в системе происходит увеличение частоты вращения. Если при разгоне частотного преобразователя до 50 Гц в течение заданного времени давление в системе не достигло нужного значения, последовательно включаются следующие основные насосы. При достижении необходимого давления в системе все насосы выключаются. Далее второй включившийся насос регулируя скорость вращения поддерживает необходимое давления в системе (при этом первый насос работает на максимум). При уменьшении расхода и увеличении давления в системе насосы отключаются в обратном порядке, и первый основной насос работает на необходимой частоте. Последовательность включения насосных агрегатов зависит от времени наработки каждого насоса. Первым запускается насос с наименьшей наработкой. При возникновении неисправности основного насоса происходит автоматическое включение резервного насоса.
Шкафы управления насосами FNB Control (каталог со схемами, 25 МБ)